The Continuous Deployment Lab provided by AT&T for Radio Edge Cloud currently has five Open Edge and three Dell servers dedicated to it. Additional servers including Dell, HP and OpenEdge are also available and/or in use but not dedicated to REC validation.
Sales Item | Description | QTY | |
NDCHW1868 | AF RMC module for OE chassis | 1 | |
NDCHW1869 | AF OE packaging for OE 3U chassis | 1 | |
NDCHW1866 | AF OE Shelf for OE chassis | 1 | |
NDCHW1861 | AF 2kW AC PSU for OE chassis (F to R) | 2 | |
NDCHW1705 | AF 25GbE dual port LP-MD2 NIC card CX5 | 5 | |
NDCHW1706 | AF 25GbE dual port OCP NIC card CX5 | 5 | |
NDCHW1527 | AF CPU heat sink type A | 5 | |
NDCHW1531 | AF 6210U Intel processor 20c 2.5GHz 150W | 5 | |
NDCHW1803 | AF OE riser card type A for OE 1U server | 5 | |
NDCHW1801 | AF OE Server L6 Barebone 1U C621 | 5 | |
NDCHW1865 | AirFrame OE 3U Chassis | 1 | |
NDCHW1395 | AF SSD 480GB SATA 1dwpd M.2 2280 | 10 | |
NDCHW1196 | AF SSD 960GB SATA 3dwpd 2.5 inch | 10 | |
NDCHW1752 | AF RDIMM DDR4 32GB 2933 | 30 |
Chassis Level Specification
Total Physical Compute Cores: 100 (200 vCPUs)
Total Physical Compute Memory: 960GB
Total SSD-based OS Storage: 4.8TB (10 x 480GB SSDs)
Total Application-based Raw Storage: 9.60TB (10 x 960GB SSD)
Networking per Server: Apps - 4 x 25GbE (per Server)
DCIM - 2 x 10GbE + 1 x 1GbT (shared)
Power: 2 x 2kW AC PSUs
Cooling: Front-to-Rear AirFlow
Shown: 3U chassis with 5 server blades (one partially removed) and two power supplies (hidden below the partially removed blade)
Shown: On server blade, 1U high by half width of a 19 inch rack