To add more Jenkins slave nodes, please follow the Akriano Jenkins guide

To setup private Jenkins, please refer to the README.md under icn/ci/

...

Hostname

CPU Model

Memory

BMC 

Firmware

Storage

1GbE: NIC#, VLAN,

(Connected

Extreme 480 switch)

10GbE: NIC# VLAN, Network

(Connected with IZ1 switch)

40GbE: NIC#

pod11-node5 (jump)

Intel

2xE5-2699

64GB

 1.46.9995

3TB (Sata)
180 (SSD)

IF0: VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)


pod11-node2

Intel

2xE5-2699

64GB

1.46.9995

3TB (Sata)
180 (SSD)

IF0: VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)


pod11-node3

Intel

2xE5-2699

64GB

1.46.9995

3TB (Sata)
180 (SSD)

IF0:  VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)

IF4: SRIOV

Virtual deployment

Hostname

CPU Model

Memory

Storage

1GbE: NIC#, VLAN,

(Connected

extreme 480 switch)

10GbE: NIC# VLAN, Network

(Connected with IZ1 switch)

pod14-node2

Intel

2xE5-2699

64GB

3TB (Sata)
180 (SSD)

IF0: VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)

Test Framework

All components are tested with end-to-end testing

...

  • Nodus provide Provider networks using VLAN networking and Service Function Chaining.
  • After the pod is up and running we will be able to attach to the pod and check for multiple interfaces created inside the container. 
  • Nodus networking is setup and created
Nodus Validation and test case results
Node Feature Discovery
  • Node Feature Discovery for Kubernetes detects hardware features available on each node in a Kubernetes cluster and advertises those features using node labels.
  • Create a pod with specific label information in the case the pods are scheduled only on nodes whose major kernel version is 3 and above. Since the NFD master and worker daemonset is already running, the master has all the label information about the nodes which is collected by the worker.
  • If the OS version matches, the Pod will be scheduled and up. Otherwise, the Pod will be in a pending state in case there are no nodes with matching labels that are requested by the Pod

...

  • Use KUD to setup 3 clusters (sdewan-hub, edge-a, edge-b)
  • Run the SDEWAN CRD Controller in each clusters.
  • Create SDEWAN CNF instance and dummy pod (using httpbin instead) in edge-a, SDEWAN CNF instance and httpbin pod in edge-b
  • Create IPSec CR to configure sdewan-hub as responder to provide virtual IP addresses to any authenticated party requesting for IP addresses through SDEWAN CRD Controller.
  • Create IPSec CR to configure edge-a and edge-b IPSec configuration to get the IP addresses through SDEWAN CRD Controller.
  • Establish edge-a tunnel to sdewan-hub, edge-b tunnel to sdewan-hub, and hub XFRM policies will automatically route traffic between edge-a and edge-b
  • Create SNAT CR to establish SNAT rule in edge-a and DNAT CR to establish DNAT rule in edge-b which will enable TCP connection from edge-a to edge-b's httpbin service.
  • Verify curl command is successful from edge-a dummy pod (using httpbin instead) to edge-b's httpbin service. The function of the curl command is to return back the ip address of the requester.

BluVal Testing

Release 6 Blueprint Scanning Status

OS Vuls Scan

  • Pass/Fail
  • Exceptions

OS Lynis Scan

  • Pass/Fail
  • Exceptions

Kube-Hunter Scan

  • Pass/Fail
  • Exceptions

See results here

Exceptions requested for the following:

  • CVE-2021-33574
  • CVE-2019-19814
  • CVE-2021-35942

Exception requests


See results here

Exceptions requested for the following:

  • BOOT-5122: GRUB boot password interferes with the unattended reboot during OS provisioning.
  • USB-2000: USB hubs and HID device must be enabled for BMC Console Redirection.
  • SSH-7408: MaxSessions of 2 prevents lynis from running under Bluval.  Lynis, etc. robot files need to be updated to handle a different port.
  • KRNL-6000: Kernel module loading required by accelerator drivers.  Forwarding required by k8s.

See results here

Pass

...