Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. PCEI Deployment Tests

Described in the PCEI R4 R5 Installation Guide

  1. PCEI End-to-End Validation Tests

...

TestDescriptionResultReference
EMCO DeploymentInstall EMCO OrchestratorPass

PCEI R4 R5 Installation Guide

Edge Cluster DeploymentDeploy Edge K8S ClustersPassPCEI R4 R5 Installation Guide
EMCO UI AccessAccess EMCO UIPassPCEI R4 R5 Installation Guide
Register Edge ClusterRegister Edge K8S Cluster with EMCOPass

PCEI R4 End-to-End Validation Guide

Create Service/AppCreate Service/App in EMCO for Azure IoT Edge, AWS GGC and PCEI Location API AppAll PASS

PCEI R4 End-to-End Validation Guide

Deploy Apps onto Edge ClustersDeploy Azure IoT Edge, AWS GGC and PCEI Location API Apps onto Edge K8S ClustersAll PASS

PCEI R4 End-to-End Validation Guide

Verify Azure IoT Edge with IoT ClientStart IoT Client, send messages to Azure IoT Edge. Monitor IoT Edge receive and decode messagesPASS

PCEI R4 End-to-End Validation Guide

Verify AWS GGC AppConfirm AWS GGC App registers with AWS IoT CoirePASS

PCEI R4 End-to-End Validation Guide

Verify PCEI Location API AppConfirm PCEI Location API App is running and responding to requestsPASS

PCEI R4 End-to-End Validation Guide

Test Procedure

PCEI R4 R5 Installation Guide

PCEI R4 End-to-End Validation Guide

...

Refer to sections of the following documents for detailed test results:

PCEI R4 R5 Installation Guide

PCEI R4 End-to-End Validation Guide

...