Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Table of Contents
outlinetrue
Introduction

...

Hostname

CPU Model

Memory

BMC 

Firmware

Storage

1GbE: NIC#, VLAN,

(Connected

extreme 480 switch)

10GbE: NIC# VLAN, Network

(Connected with IZ1 switch)

40GbE: NIC#

Jump

Intel

2xE5-2699

64GB

 1.46.9995

3TB (Sata)
180 (SSD)

IF0: VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)


node1

Intel

2xE5-2699

64GB

1.46.9995

3TB (Sata)
180 (SSD)

IF0: VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)


node2

Intel

2xE5-2699

64GB

1.46.9995

3TB (Sata)
180 (SSD)

IF0:  VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)

IF4: SRIOV

Virtual deployment

Hostname

CPU Model

Memory

Storage

1GbE: NIC#, VLAN,

(Connected

extreme 480 switch)

10GbE: NIC# VLAN, Network

(Connected with IZ1 switch)

node1

Intel

2xE5-2699

64GB

3TB (Sata)
180 (SSD)

IF0: VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)

Test Framework

All components are tested with end-to-end testing

...

  • The Optane PM plugin is Kubernetes CSI plugin and driver with storage volume provisioning for Kubernetes applications.
  • Check whether the Optane PM hardware: NVDIMM is existed, if not skip the validation.
  • Configure the Optane PM plugin in KUD, and create StorageClass and PersistentVolumeClaim which used by Kubernetes application, check whether the PVC is bound, if yes, the Optane PM volume created and bound to PVC and used by application, validation passed.
SDEWAN<To update>
  • Use Kud to setup 3 clusters (sdewan-hub, edge-a, edge-b)
  • Create SDEWAN CNF instance and dummy pod(using httpbin instead) in edge-a, SDEWAN CNF instance and httpbin pod in edge-b
  • Configure sdewan-hub as responder to provide virtual IP addresses to any authenticated party requesting for IP addresses.
  • Configure edge-a and edge-b IPSec configuration to get the IP addresses.
  • Establish edge-a tunnel to sdewan-hub, edge-b tunnel to sdewan-hub, and hub XFRM policies will automatically route traffic between edge-a and edge-b
  • Establish SNAT rule in edge-a and DNAT rule in edge-b to enable tcp connection from edge-a to edge-b's httpbin service.
  • Verify curl command is successful from edge-a dummy pod(using httpbin instead) to edge-b's httpbin service. The function of the curl command is to return back the ip address of the requester.

...