Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Table of Contents
outlinetrue
Introduction

...

SDEWAN CNF module is worked as a software-defined router located in each edge location and central hub k8s cluster to manage central-edge and edge-edge communication. It's functionality is realized via CNF (Containerized Network Function) and deployed by K8s, it is based on OpenWRT (an open-source project based on Linux, and used on embedded devices to route network traffic) and leverages Linux kernel functionality for packet processings to support network functionalities such as multiple wan link support (mwan3), firewall/SNAT/DNAT (fw3) , IPSec (strongswan) etc. It exposes Restful APIs are provided for configuration, detail information can be found at: SDEWAN CNF

SDEWAN Configure Agent module is worked as K8s controller located in each edge location and central hub k8s cluster to support configuration of SDEWAN CNF functionalities (e.g. mwan3, firwall, SNAT, DNAT, IPSec etc.) and monitor SDEWAN CNF status. It exposes CRDs to support configuration via K8s API server for unified authentication and authorization, detail information can be found at: Sdewan config Agent

Cloud Storage:

Cloud Storage which used by BPA Rest Agent to provide storage service for image objects with binary, container and operating system. There are 2 solutions, MinIO and GridFS, with the consideration of Cloud native and Data reliability, we propose to use MinIO, which is CNCF project for object storage and compatible with Amazon S3 API, and provide language plugins for client application, it is also easy to deploy in Kubernetes and flexible scale-out. MinIO also provide storage service for HTTP Server. Since MinIO need export volume in bootstrap, local-storage is a simple solution but lack of reliability for the data safety, we will switch to reliability volume provided by Ceph CSI RBD in next release. Detail information can be found at: Cloud Storage Design

...

Hostname

CPU Model

Memory

Storage

1GbE: NIC#, VLAN,

(Connected

extreme 480 switch)

10GbE: NIC# VLAN, Network

(Connected with IZ1 switch)

Jump

2xE5-2699

64GB

3TB (Sata)
180 (SSD)

IF0: VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)

node1

2xE5-2699

64GB

3TB (Sata)
180 (SSD)

IF0: VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)

node2

2xE5-2699

64GB

3TB (Sata)
180 (SSD)

IF0:  VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)

node3

2xE5-2699

64GB

3TB (Sata)
180 (SSD)

IF0: VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)

node4

2xE5-2699

64GB

3TB (Sata)
180 (SSD)

IF0: VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)

node5

2xE5-2699

64GB

3TB (Sata)
180 (SSD)

IF0: VLAN 110 (DMZ)
IF1: VLAN 111 (Admin)

IF2: VLAN 112 (Private)
VLAN 114 (Management)
IF3: VLAN 113 (Storage)
VLAN 1115 (Public)


Licensing

  • GNU/common license

...